Fluoroplastic Insulated Heat Resistant Control Cable

The fluoroplastic insulated heat resistant control cable is produced according to Q/32100KLA207-2009 standard, and it is designed for signal transmitting lines of electric apparatus and automatic control system whose rated voltage is 450/750V AC or lower.

Working Conditions
1. Rated voltage U0/U: 450/750V
2. Working temperature: The maximum long-term operating temperature of conductor is 200℃. Usually, the ambient temperature should not exceed 105℃ for PVC sheath, and 200℃ for fluoroplastic sheath.
3. Min. ambient temperature: -40℃ for fixed laying, and -15℃ for non-fixed laying.
4. Min. bending radius: 6 times of the cable outer diameter for non-armored type, and 12 times of outer diameter for armored type.

inquiry form
Technical Parameters
Item Data
Cross Section of Conductor 0.5mm2 0.75mm2 1.0mm2 1.5mm2 2.5mm2
DC Resistance of Conductor at 20℃ (Ω/km) Coating Non-tinned Tinned Non-tinned Tinned Non-tinned Tinned Non-tinned Tinned Non-tinned Tinned
A/B type 36.0 36.7 24.5 24.8 18.1 18.2 12.1 12.2 7.41 7.56
R type 39.0 40.1 26.0 26.7 19.5 20.0 13.3 13.7 7.98 8.21
Test Voltage 2500V/5min
Insulation Resistivity ≥500 MΩ·km at 20℃
Flame-retardant Property A
Type and Descriptions
Type Product Description
KFV Cu core fluoroplastic insulated 105℃ flame retardant PVC sheathed control cable
KFVP1 Cu core fluoroplastic insulated 105℃ flame retardant PVC sheathed tinned Cu wire woven shielded control cable
KFV22 Cu core fluoroplastic insulated 105℃ flame retardant PVC sheathed steel tape armored control cable
KFVX Tinned Cu core fluoroplastic insulated 105℃ flame retardant PVC sheathed control cable
KFVP1X Tinned Cu core fluoroplastic insulated 105℃ flame retardant PVC sheathed, tinned Cu wire woven shielded control cable
KFV22X Tinned Cu core fluoroplastic insulated 105℃ flame retardant PVC sheathed steel tape armored control cable
KFF F46 insulated and sheathed control cable
KFFP F46 insulated and sheathed Cu wire shielded control cable
KFFRP F46 insulated and sheathed Cu wire shielded soft control cable
Model Code Explanations
Items Code Descriptions
Series K Control cable
Insulating Material F Fluorinated ethylene propylene (F46)
Shielding Material / Without screen
P1 Tinned Cu wire
Sheathing Material V 105℃ flame retarding PVC
F F46
Armoring Material 2 Steel tape
3 Thin steel wire
Conductor / Without coating
X Tinned
Specification Core number × cross section (N×S)
N: 2, 3, 4, 5, 6, 7, 8, 9, 10, 12, 14, ……37
S: 0.5, 0.75, 1.0, 1.5, 2.5 mm2
Conductor Type (fill in the brackets) A Unistrand conductor
B Seven-strand twisted conductor
R Multi-strand soft conductor

Delivery Length
When delivering this fluoroplastic insulated control cable, the length is 1000m for product with 14 cores or fewer, while the value is 500m for product with more than 14 cores. Meanwhile, short cables with length of no less than 30m are also accepted, but the quantity should not be over 10% of the total length. Our product can be transferred at any length, and other special requirements are also negotiable. In addition, the length error is within ±0.5%.